February 22, 2025

How to prevent freezing of gas water heaters in winter?

This winter seems to be particularly cold, hot baths are essential every day, and then lying in the warm blanket, don't mention how happy. Going out is really a matter of getting angry. Winter is a rogue, frozen hands and frozen feet. In fact, antifreeze is not just for people to be more careful, but also pay attention to the use of water heaters that contribute to us. Here are a few simple things to note for everyone.

If the user purchases a normal gas water heater, when the outdoor temperature is close to or below 0 °C and encounters windy weather, the water heater must be drained after each use, and the water in the water heater should be drained to prevent damage to the water tank. Water heater. Therefore, the majority of users need to carefully read the product's instruction manual, and strictly follow the relevant requirements of the specification to use gas water heaters.

Especially when the outdoor temperature is below 0 °C, please follow the steps below to prevent the tank from freezing and cracking after each use:

1. Close the inlet valve;

2. Open the hot water valve;

3. Turn the water temperature adjustment knob to the “low temperature” or “big water” position;

4. Remove the safety valve (the safety valve is combined with the thread and the water valve body, and can be removed by left-hand rotation) to confirm that the water is completely drained. When used again, a safety valve must be installed.

While doing antifreeze, do not neglect safety inspection and protection. When no one in the house or long-term non-residence, the inlet valve should be closed and the residual water in the water heater should be vented to prevent the cold air from entering the water heater and causing water leakage, thus damaging the furniture, floor and wall in the home. An anti-downwind device can be installed in advance to prevent cold air from entering the machine to freeze the water tank. When smoke, blockage or backflow occurs in the exhaust pipe, stop using the gas water heater immediately to avoid accidents.

LNG Mass Flow Meter

ZHejiang Sealand Technology Co., Ltd. is a trustworthy manufacturer of LNG Mass Flow Meter, LNG Mass Flowmeter, LNG Flow Meter, LNG Flowmeter, LNG meter, ATEX, IECEx & CE approved.

We are the only Chinese brand who gets ATEX, and we get it from TUV SUD, the most authoritative institute for ATEX. Our meter passed all tests carried out by TUV without any modification. Their only suggestion is to replace the cable entry device with a ATEX approved one; thus, please rest assured that we produce our meter with high standard :)

Besides, Sealand meter and calibration lab are approved by CNAS, member of ilac in China.

The 1'' flow meter specification is as follows,

Specifications of Coriolis Mass Flow Meter

Model No.

CG-25

Max. flow rate

200kg/min

Nominal diameter

25mm( 1 inch)

LNG accuracy grade

±0.2%

Zero stability

0.62kg/hr

Repeatability

0.05%

Warranty

2 years

Temperature accuracy

±1°C ±0.5% of reading

Fluid temperature

-200~160°C

Packing

1set/carton

Package size

665*660*315mm

G.W.

23kgs


Please feel free to contact us if you need any other size!

LNG Mass Flow Meter, LNG Mass Flowmeter, LNG Flow Meter, LNG Flowmeter, LNG meter