As floor heating becomes more popular in the South, more and more families will install floor heating during renovations. However, there are many people who use it, and the problem arises. When people use floor heating, they often encounter problems such as floor heating leaks, loose screws, and unbalanced floor heating energy-saving effects. How do you solve these problems? Why are these problems occurring in warm weather? In fact, it is said that seven-point installation of three-point products, in fact, such as floor heating, air conditioning, such as indoor equipment, but also with the post-maintenance! We now take a look at the common problems of geothermal heating and solutions! Problem I: Water leakage due to vertical cracking of the pipeline If the pipe cracking causes water leakage, the leaking area should be found and treated in time. In addition, think of ways to dry the ground floor, you can use a high-power vacuum cleaner to absorb water, and then forced ventilation with a fan, so that the location affected by leaking air. If soaking water causes floor watering, it should be completely removed as soon as possible so that the back of the floor is dried up, and the floor and the floor are completely dry before re-paving. Problem 2: Loosen the screw on the angle valve and geothermal connection Loosening of the screws often occurs at the upper and lower bar joints of the water separator, the corner valve and the main bar connection, the corner valve handle, and the top and root of the exhaust valve. In the face of these problems, professionals should be hired to solve the problem. Problem 3: The switch of the water separator is not flexible The frequent switching on and off makes the switch inflexible. Some consumers will turn on the temperature control when they need it, and turn off the temperature control when they go out, thinking that this will save electricity. In fact, this will not only save energy, but it will consume more energy and will deplete the floor heating switch. The floor heating system is a system that operates at a low temperature, so ground-based radiant heating systems have good heat storage properties, so they do not need to be switched on and off frequently. Problem 4: The improper operation leads to loss of energy saving With the development of the material industry, the service life of floor heating is also prolonged. At present, it can basically be consistent with the life of the building. Since it is chosen, it must be ensured that no mistakes and troubles will be brought. Frequent switching not only does not achieve the energy-saving effect of the floor heating system, but also increases the operating costs of the heating system and makes the switch inflexible. If the switch is inflexible, do not solve it by yourself. Find a professional service provider for inspection and repair. . Question 5: There is gas accumulation in the pipeline of the floor heating system Because the water circulation in the floor heating pipe causes stagnant water circulation and affects the heating effect, it is possible to adjust and set the floor heating exhaust valve. Each group of radiators are equipped with a manual air release valve at the tail end. When the air is deflated, the movement should be small to prevent twisting and slowly twisting. Operate the exhaust valve and let it deflate until it discharges water. How to clean and keep warm? 1. The filter must be cleaned before use every year. The inlet and outlet valves that close the conduits are first opened, and the filter is opened after the floor is warmed up. The filter is taken out and cleaned. The filter is checked for damage and blockage. If it is bad, it should be replaced with the same size filter. OK, you can. If you are removing the filter, do not allow debris to enter the tube. 2. Floor heating pipes need to be cleaned every 2 to 3 years. The geothermal heating system mainly adopts a specially designed pipe loop structure. The shape of the pipe is complex and the pipeline is long. The temperature change of the water supply will produce calcium and magnesium ion scale, and the centralized heating will also have sludge rust, bacteria and algae, etc., if not regularly processed. Long-term adhesion to the inner wall of the pipeline will reduce the temperature of the geothermal heating system. Therefore, the use of more than two years requires regular cleaning and maintenance. 3, must be used strictly in accordance with the heating procedure. In order to prevent cracking of the water separator parts and freezing of the water in the heating pipes, it is necessary to prevent the water separator parts from freezing when not in use. After the installation of the system, the winter is not enabled. If the indoor temperature is lower than 5°C, all the water in the system should be blown out with an air compressor to prevent freezing of the system. In the winter, when the geothermal heating system is not activated, care should be taken to prevent water separation. Cracks in the parts or water in the heating pipes freeze. With regard to the relevant contents of the common problems of geothermal heating , Xiao Bian has introduced it here for everyone and hopes to help everyone! Floor heating as a large home heating equipment, in addition to the quality of the product itself, the construction of qualified accidents, we use the process of cleaning and maintenance is also essential, and reasonable use can extend the life of warm! For more information, please follow this site! Floor heating, floor heating and floor heating Gableboard,Paneling Sheets For Walls,Exhibition Of Soviet Style Architecture,Roof Tiles Shingles Huaxian Tangyu Garden Landscape Engineering Co., Ltd. , https://www.carvedbricks.com